Skip to content

Application Guide

Virus & Gene Therapy with the ARC — measurement workflows, data examples, and method guidance.

Get the Guide →

What to Measure

Three critical quality attributes for viral vector characterization

From cell culture to final formulation, viral vectors must be accurately characterized for dose, potency, and purity. Traditional methods are slow, indirect, or fail in the presence of process-related impurities.

Quality Attribute 01

Fast & easy: virus size and concentration with MRPS

MRPS repeatability for hAd5 viral titer: three technical replicates showing consistent size and concentration measurement

MRPS measurement of human adenovirus 5 (hAd5) — three technical replicates. Mean diameter ~85 nm with high repeatability across runs.

The challenge

Viruses are produced in complex biological systems alongside process-related impurities — cell debris, proteins, and extracellular vesicles. Live titer assays take days and require susceptible cell lines. Indirect methods like ELISA and SP-IRIS don’t yield accurate particle concentration in mixed matrices.

With MRPS

MRPS detects each particle electrically as it transits a microfluidic constriction. Signal is proportional to particle volume regardless of refractive index or sample complexity. Results in minutes directly from cell culture supernatant — no dilution optimization, no reference standard.

Quality Attribute 02

Virus purity and titer in a single measurement

The challenge

Viral vector preparations contain both genome-containing (full) and genome-free (empty) particles. Separating their quantification traditionally requires orthogonal assays on separate instruments — adding time, sample consumption, and opportunities for error.

With F-MRPS

The ARC adds fluorescence detection to MRPS. A membrane-permeable intercalating dye labels nucleic acid inside intact particles. Size, total concentration, and fluorescent (full) particle fraction are measured simultaneously — in a single 3 µL injection.

Example result — hAd5

Intact (full) hAd5 detected at 5.4 × 10&sup9; particles/mL — representing 64% of all particles in the measured size range.

Sample: hAd5 mixed with a broad extracellular vesicle background. Single measurement, no pre-processing.

F-MRPS fluorescence subpopulation analysis: intact hAd5 virions distinguished from total particle population by nucleic acid staining

hAd5 stained with a nucleic acid intercalating dye. Fluorescence-positive particles (intact virions) quantified as a fraction of the total size distribution in one run.

Method Comparison

How F-MRPS compares for viral vector characterization

Virus characterization demands accuracy in the presence of process impurities. DLS and NTA were designed for cleaner samples — and show it.

Comparison of F-MRPS, MRPS, DLS, and NTA for virus and gene therapy characterization

Supported Viruses

Quantify a broad range of viruses with F-MRPS

The ARC has been validated across a wide range of viral vectors and virus types. Don’t see yours? Reach out — we’re continuously expanding the list.

Spectradyne ARC: measure intact virus concentration from cell culture in minutes

Resources

Application notes and technical guides

Virus and Gene Therapy Application Guide thumbnail

Application Guide

Virus & Gene Therapy with the ARC

Step-by-step measurement protocols, data examples for viral titer and purity, and guidance for working in complex biological matrices.

Download Guide →

Ready to measure your viral vectors?

Submit a sample for a free measurement, or schedule a live demonstration with one of our applications scientists.